| 123456789101112131415161718192021222324252627282930313233343536373839404142434445464748495051525354555657585960616263646566676869707172737475767778798081828384858687888990919293949596979899100101102103104105106107108109110111112113114115116117118119120121122123124125126127128129130131132133134135136137138139140141142143144145146147148149150151152153154155156157158159160161162163164165166167168169170171172173174175176177178179180181182183184185186187188189190191192193194195196197198199200201202203204205206207208209210211212213214215216217218219220221222223224225226227228229 |
- {
- "msg": "成功",
- "code": 200,
- "data": {
- "Station_information": {
- "id": "NX_FGS_HA_FDC_STA",
- "nemCode": "NX_FGS_HA_FDC_STA",
- "name": "惠安风电场",
- "address": "吴忠市盐池县",
- "telephone": null,
- "windCapacity": 100.0,
- "windCapacityUnit": "MW",
- "windQuantityHs": 0,
- "windQuantityLd": 50,
- "capacity": 0.0,
- "capacityUnit": "kW",
- "quantityJz": 0,
- "quantityZc": 0,
- "jrwindCapacity": 100000.0,
- "jrwindCapacityUnit": "kW",
- "jrwindQuantityHs": 0,
- "jrwindQuantityLd": 50,
- "jrCapacity": 0.0,
- "jrCapacityUnit": "kW",
- "jrquantityJz": 0,
- "jrquantityZc": 0,
- "aname": "惠安风电场",
- "longitude": 106.44,
- "latitude": 37.27,
- "photo": null,
- "systemManufact": "LHDL_MF/ZC_MF",
- "headfarm": null,
- "headfarmPhone": null,
- "model": "UP2000-130/WT2000D121H85",
- "orderNum": 1,
- "height": null,
- "windType": "-1",
- "companyId": "NX_FGS",
- "regionId": "NXF_RGN",
- "groupId": "NX_FGS",
- "isAble": 1,
- "spare1": "HA",
- "spare2": null,
- "spare3": "1",
- "spare4": "1",
- "appCapacity": 1.0,
- "conCapacity": 0.0,
- "gridCapacity": 1.0,
- "hoiCapacity": 1.0,
- "firstGridTime": null,
- "wholeGridTime": null,
- "anemoNumber": null,
- "stationNumber": null,
- "xemPoint": null,
- "yemPoint": null,
- "ypoint": null,
- "xpoint": null
- },
- "mations": [
- {
- "category": "周期内核心数据",
- "content": "平均风速:3.91m/s;场站总发电量:404.27万kWh\n50台风机平均可利用率:100.0%;总损失电量:20.28万kWh\n单台平均发电量:8.09万kWh"
- },
- {
- "category": "核心结论",
- "content": "1. 性能Top3风机:1101号、1212号、2406号(单台平均发电量为9.94万kWh,平均可利用率为100.0%);\n2. 性能待优化风机(末3):2310号、2301号、1113号(单台平均发电量为6.37万kWh,平均可利用率为100.0%);\n3. 主要损失类型:限电损失电量占总损失59.4%;\n4. 优化建议:优先对1113号风机开展故障消缺,调整1113号风机切入切出风速"
- }
- ],
- "performances": [
- {
- "dbwd": "月度发电量",
- "top": "1.1101号:10.56万KWh;2.1212号:9.73万KWh;3.2406号:9.54万KWh;",
- "bottom": "1.2310号:6.28万KWh;2.2301号:6.4万KWh;3.1113号:6.43万KWh;"
- },
- {
- "dbwd": "月度风能利用率",
- "top": "1.2307号:100.0%;2.2311号:99.0%;3.2406号:99.0%;",
- "bottom": "1.1110号:86.0%;2.1210号:89.0%;3.1113号:90.0%;"
- },
- {
- "dbwd": "月度损失电量",
- "top": "1.1211号:1.98万KWh;2.1110号:0.58万KWh;3.1102号:0.57万KWh;",
- "bottom": "1.2401号:0.13万KWh;2.1205号:0.17万KWh;3.2406号:0.24万KWh;"
- }
- ],
- "cndb": {
- "targets": "对标对象:选择1101号、1212号、2406号风机",
- "indicator": "对标指标:\n 单台发电量:1101号10.56万KWh、1212号9.73万KWh、2406号2406万KWh\n 故障损失电量:1101号0.0万KWh、1212号0.0万KWh、2406号0.0万KWh\n 检修损失电量:1101号0.0万KWh、1212号0.0万KWh、2406号0.0万KWh\n 性能未达标损失电量:1101号0.13万KWh、1212号0.16万KWh、2406号0.04万KWh\n 限电损失电量:1101号0.29万KWh、1212号0.14万KWh、2406号0.2万KWh\n 受累损失电量:1101号0.0万KWh、1212号0.0万KWh、2406号0.0万KWh\n 风能利用率:1101号96.49%、1212号92.39%、2406号99.37%\n 故障损失率:1101号0.0%、1212号0.0%、2406号0.0%\n 检修损失率:1101号0.0%、1212号0.0%、2406号0.0%\n 弃风率:1101号3.0%、1212号1.0%、2406号2.0%",
- "conclusion": "对标结论:2406号与1101号风机核心差异,损失电量差0.18万kWh"
- },
- "xmdb": {
- "targets": "对标项目:惠安一期项目、惠安二期项目",
- "indicator": "对标指标:\n 项目总发电量:惠安一期项目205.54万kWh、惠安二期项目198.74万kWh\n 项目总损失电量:惠安一期项目11.87万kWh、惠安二期项目8.41万kWh\n 项目风能利用率:惠安一期项目92.51%、惠安二期项目97.26%\n 项目弃风率:惠安一期项目0.03%、惠安二期项目0.03%",
- "conclusion": "对标结论:惠安一期项目在发电量指标上优于惠安二期项目,惠安一期项目与惠安二期项目损失电量差距为3.46"
- },
- "xldb": {
- "targets": "对标线路:惠安一号集电线路、惠安二号集电线路、惠安三号集电线路、惠安四号集电线路",
- "indicator": "对标指标:\n 线路总发电量:惠安一号集电线路103.82万kWh、惠安二号集电线路101.72万kWh、惠安三号集电线路104.85万kWh、惠安四号集电线路93.89万kWh\n 线路总损失电量:惠安一号集电线路6.03万kWh、惠安二号集电线路5.84万kWh、惠安三号集电线路4.48万kWh、惠安四号集电线路3.93万kWh\n 线路风能利用率:惠安一号集电线路92.79%、惠安二号集电线路92.23%、惠安三号集电线路97.75%、惠安四号集电线路96.77%\n 线路弃风率:惠安一号集电线路3.0%、 惠安二号集电线路2.0%、 惠安三号集电线路3.0%、 惠安四号集电线路3.0%",
- "conclusion": "对标结论:惠安三号集电线路在发电量指标上优于惠安四号集电线路,损失电量差距为2.1"
- },
- "comprehensiveList": [
- {
- "category": "理论发电量",
- "month_zzl": 0.0,
- "year_zzl": 0.0,
- "trend": "red"
- },
- {
- "category": "发电量",
- "month_zzl": 0.0,
- "year_zzl": 0.0,
- "trend": "green"
- },
- {
- "category": "风能利用率",
- "month_zzl": 0.0,
- "year_zzl": 0.0,
- "trend": "red"
- },
- {
- "category": "故障损失率",
- "month_zzl": 0.0,
- "year_zzl": 0.0,
- "trend": "red"
- },
- {
- "category": "限电损失率",
- "month_zzl": 0.0,
- "year_zzl": 0.0,
- "trend": "red"
- },
- {
- "category": "MTBF",
- "month_zzl": 0.0,
- "year_zzl": 0.0,
- "trend": "red"
- },
- {
- "category": "MTTR",
- "month_zzl": 0.0,
- "year_zzl": 0.0,
- "trend": "red"
- },
- {
- "category": "复位及时率",
- "month_zzl": 0.0,
- "year_zzl": 0.0,
- "trend": "red"
- },
- {
- "category": "消缺及时率",
- "month_zzl": 0.0,
- "year_zzl": 0.0,
- "trend": "red"
- }
- ],
- "风能利用率": "场站整体风能利用率:月度95.0%,年度87.0%",
- "风能利用率Top3风机": "风能利用率Top3风机:2307号100.0%、2311号99.0%、2311号99.0%",
- "风能利用率末3风机": "风能利用率末3风机:1110号86.0%、1210号89.0%、1113号90.0%",
- "LossRatesList": [
- {
- "sslx": "维护损失",
- "zssdl": 0.27,
- "zssl": 0.0,
- "dtpjss": 0.01,
- "tbbh": 0.0
- },
- {
- "sslx": "故障损失",
- "zssdl": 0.01,
- "zssl": 0.0,
- "dtpjss": 0.0,
- "tbbh": 0.0
- },
- {
- "sslx": "限电损失",
- "zssdl": 12.05,
- "zssl": 3.0,
- "dtpjss": 0.24,
- "tbbh": 3.0
- },
- {
- "sslx": "性能损失",
- "zssdl": 7.95,
- "zssl": 2.0,
- "dtpjss": 0.16,
- "tbbh": 2.0
- },
- {
- "sslx": "受累损失",
- "zssdl": 0.0,
- "zssl": 0.0,
- "dtpjss": 0.0,
- "tbbh": 0.0
- }
- ],
- "MTBF": "MTBF(平均无故障时间):月度5974.47h,与上年同期对比±0.0%",
- "MTTR": "MTTR(平均修复时间):月度0.53h,与上年同期对比±0.0%",
- "风机可利用率": "风机可利用率:\n场站平均可利用率:月度99.99%,年度99.11%\n可利用率Top3风机:2303号99.75%、2407号99.85%、1208号99.9%\n可利用率末3风机:2303号99.75%、2407号99.85%、1208号99.9%",
- "故障统计": "故障统计:\n月度总故障次数:3次\n故障频发风机:1208号(1次)",
- "发电量分析-总发电量": "场站总发电量:月度404.27万KWh,年度19815.04万KWh",
- "发电量分析-理论发电量": "理论发电量:月度422.05万KWh,年度22189.64万KWh",
- "发电量分析-单台平均": "单台风机平均发电量:月度8.09万KWh,年度396.3万KWh",
- "发电量分析-Top3风机": "发电量Top3风机:1101号10.56万KWh、1212号9.73万KWh、2406号9.54万KWh",
- "发电量分析-末3风机": "发电量末3风机:2310号6.28万KWh、2301号6.4万KWh、1113号6.43万KWh",
- "发电量分析-同比分析": "同比/环比分析:月度发电量同比0.0%(±),环比-81.7%(±)",
- "综合场用电量分析-月度场用电量": "月度场用电量:11.11万KWh",
- "综合场用电量分析-年度场用电量": "年度场用电量:5093.57万KWh",
- "综合场用电量分析-场用电率": "场用电率:月度2.79%,年度1.4%",
- "综合场用电量分析-与同期对比": "与同期对比:月度场用电量同比0.0%(±),场用电率同比0.0%(±)",
- "风资源分析-风资源数据": "风资源数据:\n平均风速:3.9m/s\n主导风向:188.38\n静风频率:0.41%",
- "风资源分析-历史对比": "历史对比:与去年同期相比,平均风速0.0m/s(±),静风频率0.0%(±)",
- "曲线偏差率分析": "偏差率排行(排名前三):\n1101号风机:偏差率10.44%,排名: 1\n2310号风机:偏差率9.31%,排名: 2\n2303号风机:偏差率9.16%,排名: 3",
- "各区间偏差率统计": "各区间偏差率统计:\n3-5m/s区间:平均偏差率0.21%,偏差率最大风机:1211号,偏差率最小风机:2301号\n5-11m/s区间:平均偏差率-0.06%,偏差率最大风机:2310号,偏差率最小风机:1211号\n11-25m/s区间:平均偏差率0.0%,偏差率最大风机:2310号,偏差率最小风机:1211号",
- "单台风速分析": "单台风速分析(排名前三):\n2411号风机:月度小风切入风速2.62m/s、小风切出风速2.52m/s\n2405号风机:月度小风切入风速2.89m/s、小风切出风速2.76m/s\n1206号风机:月度小风切入风速2.92m/s、小风切出风速2.03m/s",
- "合格率计算": "合格率计算:\n50台风机平均切入切出合格率38.41%\n合格率100%的风机:0台,为\n合格率低于60%的风机:2台,为2405,2411",
- "拟合优度排行": "拟合优度排行:\n月拟合优度Top3:1212号56.73%、1210号55.55%、1202号54.82%\n月拟合优度末3:2306号7.27%、2410号11.91%、2311号11.91%",
- "拟合优度排行—上月": "拟合优度排行—上月:\n月拟合优度Top3:2301号34.7%、2411号33.97%、2313号33.37%\n月拟合优度末3:1106号17.13%、2406号18.2%、2309号20.33%",
- "单机月度分析-分析对象": "2401、2402、2301、2401、2402、2301、号风机",
- "单机月度分析-关键数据": "关键数据:\nTop3:2401号 机组功率一致性91.92%,设备利用小时:40.4h\n2402号 机组功率一致性91.93%,设备利用小时:35.76h\n2301号 机组功率一致性92.64%,设备利用小时:31.98h\n末3:2401号 机组功率一致性91.92%,设备利用小时:40.4h\n2402号 机组功率一致性91.93%,设备利用小时:35.76h\n2301号 机组功率一致性92.64%,设备利用小时:31.98",
- "单机月度分析-关键数据上月": "关键数据-上月:\nTop3:2411号 机组功率一致性91.43%,设备利用小时:208.46h\n2402号 机组功率一致性91.46%,设备利用小时:197.27h\n2401号 机组功率一致性91.61%,设备利用小时:249.4h\n末3:2411号 机组功率一致性91.43%,设备利用小时:208.46h\n2402号 机组功率一致性91.46%,设备利用小时:197.27h\n2401号 机组功率一致性91.61%,设备利用小时:249.4",
- "性能等级评估": "等级分布:\nA级(优秀):28台(2304,1112,1113号等)\nB级(良好):22台(2308,2312,1107号等)\nC级(合格):0台(号等)",
- "复位及时率": "月度5分钟: 复位次数 136.0次,复位及时率:97.84%\n月度10分钟:复位次数137.0次,复位及时率:98.56%\n月度15分钟:复位次数137.0次,复位及时率:98.56%\n月度20分钟:复位次数137.0次复位及时率:98.56%\n月度5分钟复位次数排名最低的三台风机:1102号(0.0次)、1101号(0.0次)、1104号(0.0次)\n与上月对比:月度5分钟复位及时率环比-2.16%(±)",
- "消缺及时率": "月度故障次数:111.0次\n月度消缺及时次数:111.0次\n月度消缺及时率:100.0%\n年度消缺及时率:99.97%\n与上月对比:月度环比0.0%(±)",
- "状态转换率-大于3米风速": "大于3米风速转换次数及转换率:\n5分钟:转换次数为85.0次,转换率为3.58%\n10分钟:转换次数为108.0次,转换率为4.55%\n15分钟:转换次数为136.0次,转换率为5.73%\n20分钟:转换次数为158.0次,转换率为6.66%",
- "状态转换率-月度5分钟": "大于3米风速转换次数及转换率:\n5分钟:转换次数为85.0次,转换率为3.58%\n10分钟:转换次数为108.0次,转换率为4.55%\n15分钟:转换次数为136.0次,转换率为5.73%\n20分钟:转换次数为158.0次,转换率为6.66%",
- "状态转换率-与上月对比": "大于3米风速转换次数及转换率:\n5分钟:转换次数为85.0次,转换率为3.58%\n10分钟:转换次数为108.0次,转换率为4.55%\n15分钟:转换次数为136.0次,转换率为5.73%\n20分钟:转换次数为158.0次,转换率为6.66%"
- }
- }
|